| 123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194195196197198199200201202203204205206207208209210211212213214215216217218219220221222223224225226227228229230231232233234235236237238239240241242243244245246247248249250251252253254255256257258259260261262263264265266267268269270271272273274275276277278279280281282283284285286287288289290291292293294295296 |
- PTS test results for HDP
- PTS version: 6.1
- Tested: 08-May-2015
- Android version: 5.1
- Results:
- PASS test passed
- FAIL test failed
- INC test is inconclusive
- N/A test is disabled due to PICS setup
- -------------------------------------------------------------------------------
- Test Name Result Notes
- -------------------------------------------------------------------------------
- TC_SRC_CON_BV_01_I PASS haltest:
- hl register_application <args>
- for instance:
- hl register_application health intel heartrate
- heartrate-monitor 1 BTHL_MDEP_ROLE_SOURCE 4100
- BTHL_CHANNEL_TYPE_RELIABLE testing
- when prompted:
- bluetooth ssp_reply <args>
- for instance:
- bluetooth ssp_reply <bdaddr>
- BT_SSP_VARIANT_CONSENT 1
- Note: IUT must be discoverable, connectable
- TC_SRC_CON_BV_02_I PASS Note: IUT must be in discoverable mode
- TC_SRC_CON_BV_03_I PASS when prompted: bluetooth ssp_reply <args>
- TC_SRC_CON_BV_04_I PASS haltest:
- hl connect_channel <app_id> <bd_addr>
- <mdep_cfg_index>
- when prompted: bluetooth ssp_reply <args>
- TC_SRC_CON_BV_05_I PASS when prompted: bluetooth ssp_reply <args>
- Note: IUT must be in connectable mode
- TC_SRC_CON_BV_06_I PASS haltest:
- hl connect_channel <app_id> <bd_addr>
- <mdep_cfg_index>
- when prompted: bluetooth ssp_reply <args>
- TC_SRC_CON_BV_07_I PASS bluetooth start_discovery
- Note: PTS HDP device must be discovered
- TC_SRC_CON_BV_08_I PASS bluetooth remove_bond <PTS addr>
- when prompted: bluetooth ssp_reply <args>
- TC_SRC_CON_BV_09_I PASS haltest:
- hl connect_channel <app_id> <bd_addr>
- <mdep_cfg_index>
- when prompted: bluetooth ssp_reply <args>
- TC_SRC_CON_BV_10_I N/A
- TC_SRC_CC_BV_01_C PASS haltest:
- hl connect_channel <app_id> <bd_addr>
- <mdep_cfg_index>
- when prompted: bluetooth ssp_reply <args>
- TC_SRC_CC_BV_02_C PASS when prompted: bluetooth ssp_reply <args>
- Note: IUT must be discoverable, connectable
- TC_SRC_CC_BV_03_C PASS haltest:
- hl register_application bluez-android Bluez
- bluez-hdp health-device-profile 1
- BTHL_MDEP_ROLE_SOURCE 4100
- BTHL_CHANNEL_TYPE_RELIABLE pulse-oximeter
- hl connect_channel <app_id> <bd_addr>
- <mdep_cfg_index>
- when prompted: bluetooth ssp_reply <args>
- TC_SRC_CC_BV_05_C PASS haltest:
- hl register_application bluez-android Bluez
- bluez-hdp health-device-profile 1
- BTHL_MDEP_ROLE_SOURCE 4100
- BTHL_CHANNEL_TYPE_RELIABLE pulse-oximeter
- Note: IUT must be discoverable, connectable
- TC_SRC_CC_BV_07_C PASS haltest:
- hl register_application bluez-android Bluez
- bluez-hdp health-device-profile 2
- BTHL_MDEP_ROLE_SOURCE 4100
- BTHL_CHANNEL_TYPE_RELIABLE pulse-oximeter
- BTHL_MDEP_ROLE_SOURCE 4100
- BTHL_CHANNEL_TYPE_STREAMING pulse-oximeter
- hl connect_channel <app_id> <bd_addr>
- <mdep_cfg_index>
- when prompted: bluetooth ssp_reply <args>
- when prompted:
- hl connect_channel <app_id> <bd_addr>
- <mdep_cfg_index>
- TC_SRC_CC_BV_09_C PASS haltest:
- hl register_application bluez-android Bluez
- bluez-hdp health-device-profile 2
- BTHL_MDEP_ROLE_SOURCE 4100
- BTHL_CHANNEL_TYPE_RELIABLE pulse-oximeter
- BTHL_MDEP_ROLE_SOURCE 4100
- BTHL_CHANNEL_TYPE_STREAMING pulse-oximeter
- when prompted: bluetooth ssp_reply <args>
- Note: IUT must be discoverable, connectable
- TC_SRC_CC_BI_12_C PASS haltest:
- hl register_application bluez-android Bluez
- bluez-hdp health-device-profile 1
- BTHL_MDEP_ROLE_SOURCE 4100
- BTHL_CHANNEL_TYPE_RELIABLE pulse-oximeter
- Note: IUT must be discoverable, connectable
- TC_SRC_HCT_BV_01_I PASS haltest:
- hl register_application bluez-android Bluez
- bluez-hdp health-device-profile 1
- BTHL_MDEP_ROLE_SOURCE 4100
- BTHL_CHANNEL_TYPE_RELIABLE pulse-oximeter
- hl connect_channel <app_id> <bd_addr>
- <mdep_cfg_index>
- when prompted: bluetooth ssp_reply <args>
- TC_SRC_HCT_BV_02_I PASS haltest:
- hl register_application bluez-android Bluez
- bluez-hdp health-device-profile 1
- BTHL_MDEP_ROLE_SOURCE 4100
- BTHL_CHANNEL_TYPE_RELIABLE pulse-oximeter
- Note: IUT must be discoverable, connectable
- TC_SRC_HCT_BV_03_I N/A
- TC_SRC_HCT_BV_04_I PASS haltest:
- hl register_application bluez-android Bluez
- bluez-hdp health-device-profile 1
- BTHL_MDEP_ROLE_SOURCE 4100
- BTHL_CHANNEL_TYPE_RELIABLE pulse-oximeter
- when prompted: bluetooth ssp_reply <args>
- Note: IUT must be discoverable, connectable
- TC_SRC_HCT_BV_05_C N/A
- TC_SRC_HCT_BV_06_C PASS haltest:
- hl register_application bluez-android Bluez
- bluez-hdp health-device-profile 1
- BTHL_MDEP_ROLE_SOURCE 4100
- BTHL_CHANNEL_TYPE_RELIABLE pulse-oximeter
- when prompted: bluetooth ssp_reply <args>
- Note: IUT must be discoverable, connectable
- TC_SRC_HCT_BV_07_C PASS haltest:
- hl register_application bluez-android Bluez
- bluez-hdp health-device-profile 1
- BTHL_MDEP_ROLE_SOURCE 4100
- BTHL_CHANNEL_TYPE_RELIABLE pulse-oximeter
- TC_SRC_DE_BV_01_I N/A
- TC_SRC_DE_BV_02_I PASS haltest:
- hl register_application bluez-android Bluez
- bluez-hdp health-device-profile 1
- BTHL_MDEP_ROLE_SOURCE 4100
- BTHL_CHANNEL_TYPE_RELIABLE pulse-oximeter
- Note: IUT must be discoverable, connectable
- TC_SRC_DEP_BV_01_I N/A
- TC_SRC_DEP_BV_02_I N/A
- TC_SNK_CON_BV_01_I PASS haltest:
- hl register_application <args>
- for instance:
- hl register_application health intel heartrate
- heartrate-monitor 1 BTHL_MDEP_ROLE_SINK 4100
- BTHL_CHANNEL_TYPE_RELIABLE testing
- when prompted:
- bluetooth ssp_reply <args>
- for instance:
- bluetooth ssp_reply <bdaddr>
- BT_SSP_VARIANT_CONSENT 1
- Note: IUT must be discoverable, connectable
- TC_SNK_CON_BV_02_I PASS Note: IUT must be discoverable, connectable
- TC_SNK_CON_BV_03_I PASS when prompted: bluetooth ssp_reply <args>
- Note: IUT must be discoverable, connectable
- TC_SNK_CON_BV_04_I PASS haltest:
- hl connect_channel <app_id> <bd_addr>
- <mdep_cfg_index>
- when prompted: bluetooth ssp_reply <args>
- Note: IUT must be discoverable, connectable
- TC_SNK_CON_BV_05_I PASS when prompted: bluetooth ssp_reply <args>
- TC_SNK_CON_BV_06_I PASS haltest:
- hl connect_channel <app_id> <bd_addr>
- <mdep_cfg_index>
- when prompted: bluetooth ssp_reply <args>
- TC_SNK_CON_BV_07_I PASS bluetooth start_discovery
- TC_SNK_CON_BV_08_I PASS bluetooth remove_bond <PTS addr>
- when prompted: bluetooth ssp_reply <args>
- Note: IUT must be discoverable, connectable
- TC_SNK_CON_BV_09_I PASS haltest:
- hl connect_channel <app_id> <bd_addr>
- <mdep_cfg_index>
- when prompted: bluetooth ssp_reply <args>
- TC_SNK_CON_BV_10_I N/A
- TC_SNK_CC_BV_01_C PASS haltest:
- hl connect_channel <app_id> <bd_addr>
- <mdep_cfg_index>
- when prompted: bluetooth ssp_reply <args>
- TC_SNK_CC_BV_02_C PASS when prompted: bluetooth ssp_reply <args>
- Note: IUT must be discoverable, connectable
- TC_SNK_CC_BV_04_C PASS haltest:
- hl register_application bluez-android Bluez
- bluez-hdp health-device-profile 1
- BTHL_MDEP_ROLE_SINK 4100
- BTHL_CHANNEL_TYPE_RELIABLE pulse-oximeter
- hl connect_channel <app_id> <bd_addr>
- <mdep_cfg_index>
- when prompted: bluetooth ssp_reply <args>
- TC_SNK_CC_BV_06_C PASS haltest:
- hl register_application bluez-android Bluez
- bluez-hdp health-device-profile 2
- BTHL_MDEP_ROLE_SINK 4100 BTHL_CHANNEL_TYPE_RELIABLE
- pulse-oximeter
- BTHL_MDEP_ROLE_SINK 4100 BTHL_CHANNEL_TYPE_STREAMING
- pulse-oximeter
- TC_SNK_CC_BV_08_C PASS haltest:
- hl register_application bluez-android Bluez
- bluez-hdp health-device-profile 2
- BTHL_MDEP_ROLE_SINK 4100
- BTHL_CHANNEL_TYPE_RELIABLE pulse-oximeter
- BTHL_MDEP_ROLE_SINK 4100
- BTHL_CHANNEL_TYPE_STREAMING pulse-oximeter
- hl connect_channel <app_id> <bd_addr>
- <mdep_cfg_index>
- when prompted: bluetooth ssp_reply <args>
- when prompted:
- hl connect_channel <app_id> <bd_addr>
- <mdep_cfg_index>
- TC_SNK_CC_BV_10_C PASS haltest:
- hl register_application bluez-android Bluez
- bluez-hdp health-device-profile 2
- BTHL_MDEP_ROLE_SINK 4100 BTHL_CHANNEL_TYPE_RELIABLE
- pulse-oximeter
- BTHL_MDEP_ROLE_SINK 4100 BTHL_CHANNEL_TYPE_STREAMING
- pulse-oximeter
- Note: IUT must be discoverable, connectable
- TC_SNK_CC_BI_11_C PASS haltest:
- hl register_application bluez-android Bluez
- bluez-hdp health-device-profile 1
- BTHL_MDEP_ROLE_SINK 4100
- BTHL_CHANNEL_TYPE_RELIABLE pulse-oximeter
- Note: IUT must be discoverable, connectable
- TC_SNK_HCT_BV_01_I PASS haltest:
- hl register_application bluez-android Bluez
- bluez-hdp health-device-profile 1
- BTHL_MDEP_ROLE_SINK 4100
- BTHL_CHANNEL_TYPE_RELIABLE pulse-oximeter
- hl connect_channel <app_id> <bd_addr>
- <mdep_cfg_index>
- when prompted: bluetooth ssp_reply <args>
- TC_SNK_HCT_BV_02_I PASS haltest:
- hl register_application bluez-android Bluez
- bluez-hdp health-device-profile 1
- BTHL_MDEP_ROLE_SINK 4100
- BTHL_CHANNEL_TYPE_RELIABLE pulse-oximeter
- Note: IUT must be discoverable, connectable
- TC_SNK_HCT_BV_03_I N/A
- TC_SNK_HCT_BV_04_I PASS haltest:
- hl register_application bluez-android Bluez
- bluez-hdp health-device-profile 1
- BTHL_MDEP_ROLE_SINK 4100
- BTHL_CHANNEL_TYPE_RELIABLE pulse-oximeter
- when prompted: bluetooth ssp_reply <args>
- Note: IUT must be discoverable, connectable
- TC_SNK_HCT_BV_05_C N/A
- TC_SNK_HCT_BV_06_C PASS haltest:
- hl register_application bluez-android Bluez
- bluez-hdp health-device-profile 1
- BTHL_MDEP_ROLE_SINK 4100
- BTHL_CHANNEL_TYPE_RELIABLE pulse-oximeter
- Note: IUT must be discoverable, connectable
- TC_SNK_HCT_BV_07_C PASS haltest:
- hl register_application bluez-android Bluez
- bluez-hdp health-device-profile 1
- BTHL_MDEP_ROLE_SINK 4100
- BTHL_CHANNEL_TYPE_RELIABLE pulse-oximeter
- Note: IUT must be discoverable, connectable
- TC_SNK_DE_BV_01_I N/A
- TC_SNK_DE_BV_02_I PASS haltest:
- hl register_application bluez-android Bluez
- bluez-hdp health-device-profile 1
- BTHL_MDEP_ROLE_SINK 4100
- BTHL_CHANNEL_TYPE_RELIABLE pulse-oximeter
- Note: IUT must be discoverable, connectable
- TC_SNK_DEP_BV_03_I N/A
- TC_SNK_DEP_BV_04_I N/A
- -------------------------------------------------------------------------------
|